XPA 2001

XPA 2001

Mã sản phẩm: XPA 2001

Mono 70/100 V Amplifier - 200 Watts

Giá bán: Liên hệ...
Số lượng
Hướng dẫn mua hàng

HOTLINE: 0986.728.400

Làm việc, 8:30 - 17:30 Từ Thứ 2 đến thứ 6.
Tư vẫn - mua hàng

The Extron XTRA™ Series XPA 2001 is a half rack 1U, convection cooled power amplifier delivering 200 watts into a 70 volt or 100 volt line. This professional grade amplifier features a 100 dB signal-to-noise ratio with less than 0.1% THD+N. The XPA 2001 is an ENERGY STAR® qualified amplifier with an Extron exclusive, highly efficient, advanced Class D amplifier design. It also features patented CDRS™ - Class D Ripple Suppression technology that provides a smooth, clean audio waveform and an improvement in signal fidelity over conventional Class D amplifiers. The XPA 2001 is housed in a half rack width metal enclosure, conserving rack space and weighing only 2.5 lbs (1.1 kg). The Extron exclusive, high efficiency design generates very little heat and allows the amplifier to be convection cooled.

 

Energy Efficient Amplifier with Auto Power-Down

The XPA 2001 ENERGY STAR qualified amplifier is an energy efficient product that conserves energy and reduces costs. With an auto power-down feature that automatically places the amplifier into standby after 25 minutes of inactivity, it consumes just 10 watts when idle and less than 1 watt in standby mode.

The XPA 2001 is housed in a compact 1U, half rack width enclosure. This amplifier is UL 2043 plenum rated when used with the optional Flexible Conduit Adapter Kit, allowing for a concealed installation above a drop ceiling to prevent theft while providing convenient placement of AV equipment.

The XPA 2001 delivers 200 watts rms for high impedance speaker systems in voice reinforcement and distributed audio applications. The XPA 2001 is available in 70 volt and 100 volt models.

The XPA 2001 accepts balanced and unbalanced input signals and includes recessed, detented level controls located on the rear panel to prevent tampering. These controls allow for adjusting audio system gain structure, or setting individual levels for each zone. For applications requiring volume adjustment and muting control from a location other than the amplifier, remote control capability is available using the optional Extron VCM 100 or VCM 200 analog volume and mute controller or VC 50 analog volume controller. Additionally, the XPA 2001 includes multiple protection circuits that momentarily activate when an abnormal condition, such as overheating, is detected. An advanced, automatic clip limiter protects speakers from clipping distortion.

 

Features

  • Inputs: Balanced or unbalanced stereo or mono on a 3.5 mm, 5-pole captive screw connector
  • Speaker Outputs: Screw-lock, 5 mm, 2-pole captive screw connector
  • 200 watts rms output power:
    XPA 2001-70V - 1 x 200 watts @ 70 volts
    XPA 2001-100V - 1 x 200 watts @ 100 volts
     — The XPA 2001 provides ample power output for larger rooms.
  • ENERGY STAR® qualified amplifier — The XPA 2001 is an ENERGY STAR qualified amplifier and energy efficient product that conserves energy and reduces costs.
  • Professional grade signal-to-noise and THD+N performance — The XPA 2001 delivers professional grade performance with 100 dB signal-to-noise ratio and THD+N of less than 0.1%.
  • Extron Patented CDRS™ - Class D Ripple Suppression — CDRS is an Extron Patented technology that provides a smooth, clean audio waveform and an improvement in signal fidelity over conventional Class D amplifier designs. CDRS eliminates the high frequency switching ripple characteristic of Class D amplifiers, a source of RF emissions which can interfere with sensitive AV equipment such as wireless microphones.
  • Convection cooled, fanless operation — The XPA 2001 does not require internal fans or vents for cooling, ensuring quiet, reliable operation. It generates substantially less heat than conventional power amplifiers, making it ideal for rack-mount applications.
  • Ultra low inrush current - no need for power sequencing — Allows multiple XTRA Series amplifiers to be powered on simultaneously without overloading power circuits. This eliminates the need for power sequencing.
  • Power factor correction - removes harmonic content on AC line — The XPA 2001 features power factor correction technology that smoothes out the high peak currents of the amplifier’s current draw, thus minimizing the presence of high frequency harmonics on the AC power line, and therefore preventing audible artifacts from being transmitted to other audio equipment in the system.
  • Rack-mountable 1U, half rack width enclosure — The XPA 2001 reduces rack space requirements for many installations.
  • UL 2043 plenum rated when used with optional Flexible Conduit Adapter Kit — The XPA 2001 meets UL 2043 for smoke and heat release for installation within a plenum airspace above a drop ceiling when used with the optional Flexible Conduit Adapter Kit, part # 70-228-02. Above-the-ceiling placement conceals the amplifier to prevent theft, and is convenient for installing equipment when space inside the room is limited.
  • Auto power-down with fast power-up — The XPA 2001 meets ENERGY STAR qualification requirements with an auto power-down feature that automatically places the amplifier into standby after 25 minutes of inactivity, dramatically reducing power consumption. It quickly returns to full power status in less than one second upon signal detection.
  • Rear panel recessed, detented level control — Provides attenuation of input signals for adjusting audio system gain staging. It is located on the rear panel to prevent users from tampering with level adjustments.
  • Automatic clip limiter — Detects actual onset of clipping by comparing input and output waveforms. Gain is automatically reduced without audible artifacts to protect speakers from clipping distortion.
  • Multiple protection circuits — Activate during output shorts, thermal overload, or DC faults to prevent damage to the amplifier and speakers.
  • Remote standby port — Enables the XPA 2001 to be remotely powered down when not in use, reducing operating cost.
  • Remote volume and mute control port — In basic installations without control systems, this port allows the XPA 2001 to be remotely controlled using the optional Extron VCM 100 or VCM 200 analog volume and mute controller or VC 50 analog volume controller.
  • Input summing — Actively sums incoming left and right channel signals for mono amplification.
  • High pass filter — This switch selectable filter rolls off frequencies below 80 Hz to prevent saturation of speaker transformers.
  • 5 mm screw-lock captive screw speaker connectors — Enable simple, secure connections with 22 to 12 AWG speaker cables.
  • Front and rear-mounted signal and protection indication LEDs — Provide convenient indication of input signal presence and protection circuit activation from both sides of an equipment rack.
  • Front panel over-temperature LED — Provides visual indication that the enclosure temperature has exceeded the optimal value, well in advance of the onset of thermal protection circuitry.
  • Internal Extron Everlast™ power supply — Provides worldwide power compatibility, with high‑demonstrated reliability and low power consumption for reduced operating cost
  • Extron Everlast Power Supply is covered by a 7‑year parts and labor warranty
XPA 2001 Series
 
Audio
   Voltage gain   
      XPA 2001-70V  57x (35 dB)
      XPA 2001-100V  81x (38 dB)
   Stereo channel separation  >75 dB @ 1 kHz
   CMRR  75 dB @ 1 kHz (typical)
 
Audio input
   Number/signal type  1 stereo or 2 mono, balanced/unbalanced
   Connectors  (1) 3.5 mm captive screw connector, 5 pole
   Impedance  >10k ohms unbalanced/balanced, DC coupled
   Nominal level  +4 dBu (1.23 Vrms), balanced
   Maximum level  +20 dBu (7.75 Vrms), balanced
   Input sensitivity  +4 dBu (1.23 Vrms) if driven by one input
-2 dBu (0.615 Vrms) if both inputs are summed
   Input signal detection threshold  -40 dBu ±3 dB, balanced
    NOTE     0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV ≈ 2 dBu
 
Audio output
   Number/signal type   
      XPA 2001-70V  1 mono, 70 V line
      XPA 2001-100V  1 mono, 100 V line
   Connectors  (1) 5 mm screw lock captive screw connector, 2 pole
    NOTE     These connectors accept wires of 22 AWG to 12 AWG.
   Load impedance
      XPA 2001-70V  25 ohms minimum
      XPA 2001-100V  50 ohms minimum
   Amplifier type  Class D
   Output power
      XPA 2001-70V  200 watts rms, 70 V, 1 kHz, <0.1% THD
      XPA 2001-100V  200 watts rms, 100 V, 1 kHz, <0.1% THD
   Frequency response  20 Hz to 20 kHz, ±1 dB
   THD + Noise  <0.1% @ 1 kHz at 3 dB below clipping
   S/N  100 dB, 20 Hz - 20 kHz, unweighted
   Damping factor   
      XPA 2001-70V  >100 @ 25 ohms
      XPA 2001-100V  >100 @ 50 ohms
   High pass filter  80 Hz, 12 dB per octave rolloff (switch selectable)
 
Control/remote — amplifier
   Control port  (1) 3.5 mm captive screw connector, 5 pole
   Pin configurations   
      DC volume control (analog)  Pin 1 = +10 VDC, 50 mA (max.), pin 2 = volume/mute (variable voltage), pin 3 = GND
      Volume control voltage range  0 V (mute) to 10 V (maximum volume)
      Standby power control (contact closure)  Pin 4 = GND, pin 5 = standby
 
General
   Power supply  Internal
Input: 100-240 VAC, 50-60 Hz
   Power consumption and thermal dissipation   
      XPA 2001-70V
  115 VAC, 60Hz 230 VAC, 50Hz
AC Line
Current
AC Power
Consumed
Thermal
Dissipation
AC Line
Current
AC Power
Consumed
Thermal
Dissipation
Condition A W W BTU/hr A W W BTU/hr
Active (1/8 power), all
channels driven
70 V 0.4 42.2 17.2 59 0.3 43.3 18.3 62
Quiescent (idle) 0.2 9.5 9.5 32 0.1 10.2 10.2 35
Standby <0.1 <1 <1 <3 <0.1 <1 <1 <3
      XPA 2001-100V
  115 VAC, 60Hz 230 VAC, 50Hz
AC Line
Current
AC Power
Consumed
Thermal
Dissipation
AC Line
Current
AC Power
Consumed
Thermal
Dissipation
Condition A W W BTU/hr A W W BTU/hr
Active (1/8 power), all
channels driven
100 V 0.4 43.7 18.7 64 0.4 44.8 19.8 68
Quiescent (idle) 0.1 11.9 11.9 41 0.1 11.9 11.9 40
Standby <0.1 <1 <1 <3 <0.1 <1 <1 <3
   Temperature/humidity  Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
   Cooling  Convection, no vents, with internal heat sinks
   Protection  Clip limiting, thermal, short circuit, DC output
   Indication  Limiter/Protect LED indicates the onset of clip limiting, thermal cycling, or a short circuit
   Mounting   
      Rack mount  Yes, with optional 1U rack shelf
   Enclosure type  Metal
   Enclosure dimensions  1.7" H x 8.7" W x 9.5" D (1U high, half rack wide)
(4.3 cm H x 22.1 cm W x 24.1 cm D)
   Product weight  2.5 lbs (1.1 kg)
   Vibration  ISTA 1A in carton (International Safe Transit Association)
   Regulatory compliance   
      Safety  BSMI, CCC, CE, c-UL, GS, KC Mark, PSE, S Mark, UL
UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release; meets UL 60065, IEC 60065, and BSEN 60065 for AV equipment.
      EMI/EMC  CE, CISPR 22 Class B, C-tick, FCC Class B, ICES, KCC, VCCI Class B
      Environmental  Complies with the appropriate requirements of ENERGY STAR® (ENERGY STAR qualified amplifier), EU code of conduct, RoHS, WEEE
   Product warranty  3 years parts and labor
   Everlast power supply warranty  7 years parts and labor
    NOTE     All nominal levels are at ±10%.
    NOTE     Specifications are subject to change without notice.
(082217-D24)
Shipping Dimensions and Weights
    Part # Height Width Depth Weight
    60-850-01 4.25" (10.8 cm) 14.0" (35.6 cm) 13.0" (33.0 cm) 4.38 lbs (1.99 kg)
    60-850-11 4.25" (10.8 cm) 14.0" (35.6 cm) 13.0" (33.0 cm) 4.38 lbs (1.99 kg)

Sản phẩm cùng loại

MPA 601

Liên hệ...

XPA U 1004 SB

Liên hệ...

XPA U 2002 SB

Liên hệ...

XPA U 3502

Liên hệ...

XPA U 358

Liên hệ...

XPA U 758

Liên hệ...

XPA 1002

Liên hệ...

XPA 2002

Liên hệ...

XPA 2003C

Liên hệ...

XPA 2004

Liên hệ...

Đăng ký Email để nhận thông báo mới nhất

Copyright 2015 © www.duyhoaphat.vn. All rights reserved.

Loading... Loading ...